Abus FU9001 Especificaciones

Busca en linea o descarga Especificaciones para Los Sistemas De Control De Acceso De Seguridad Abus FU9001. ABUS FU9001 security or access control system Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 101
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
ABUS WIRELESS ALARM SYSTEM
INSTALLATION INSTRUCTION
These installation instructions are an important product accessory. They contain important installation and operation
information. Bear this in mind if you pass the product on to others.
Store these installation instructions in a safe place for future reference.
For a list of contents with page numbers, see page 3.
For brief instructions of starting up the ABUS wireless alarm package, see page 10-91.
Vista de pagina 0
1 2 3 4 5 6 ... 100 101

Indice de contenidos

Pagina 1 - INSTALLATION INSTRUCTION

ABUS WIRELESS ALARM SYSTEM INSTALLATION INSTRUCTION These installation instructions are an

Pagina 2 - 5INWSAIMABEN-B

3-10 3.5 How can the ABUS wireless alarm system be extended? The ABUS wireless alarm system is a modular, extendable security system. The following gr

Pagina 3 - Contents

11-100 EVENT MESSAGE DESCRIPTION Restore Z=XXX Alarm restore in zone No. XXX Remote arm:P=X Partition X armed from the UD software Rmt disarm:P=X

Pagina 4

11-101

Pagina 5

3-11 3.6 CE manufacturer’s declaration EG – KONFORMITÄTSERKLÄRUNG EC – DECLARATION OF CONFIRMITY Wir / We Security-Cen

Pagina 6 - Chapter 2 Safety information

4-12 Chapter 4 Initial considerations Before starting to install your new ABUS wireless alarm system, please take the time to consider the following.

Pagina 7

4-13 4.1 What kinds of security are there? In general, there are three different ways of securing an object: External perimeter surveillance, in whic

Pagina 8

4-14 4.2 What wireless detectors do I need? The type and number of wireless detectors needed depends partly on the type of protection and partly on th

Pagina 9

5-15 Chapter 5 Installing the ABUS wireless alarm system Make a sketch of the object or use the architect’s plans. Enter the absolutely necessary wire

Pagina 10

5-16 5.2 How do I install the ABUS wireless alarm system? The ABUS wireless alarm system is mounted on the wall in three steps. You need a flat screwd

Pagina 11

5-17 5.2.3 Fixing the faceplate Before fixing the faceplate, first read the following sections (up to page 5-20) and then return here. The preceding s

Pagina 12

5-18 5.5 How do I connect the other contacts in the ABUS wireless alarm system? 5.5.1 Connecting a wired sounder The ABUS wireless alarm system is fit

Pagina 13

5-19 NOTE: 1. You can connect external equipment to clamp N.O instead of to clamp N.C. If you connect to clamp NC (normally closed), the circuit

Pagina 14

ABUS WIRELESS ALARM SYSTEM These installation instructions are published by ABUS Security-Center GmbH & Co. KG, Linker Kreuthweg 5, D-86444 Affing

Pagina 15

5-20 5.6 How are the standby batteries used? The ABUS alarm system is equipped with 6 standby batteries that maintain operation during a power failure

Pagina 16

5-21 5.7 What are the effects of the different jumper settings? The PC board of the ABUS wireless alarm system is fitted with internal jumpers. Config

Pagina 17

7-22 Chapter 6 Programming the ABUS wireless alarm system There are several ways of programming your ABUS wireless alarm system: • At the alarm syste

Pagina 18

7-23 7.2 11 System Under System, you make settings that affect the entire system. This is an overview of the menu options according to their sequence

Pagina 19

7-24 Timers: Quick-Key Parameter Default Range 11 11 22 Exit/Entry delay 2 Exit and entry delay times of Group 2. Make these settings as for Group 1

Pagina 20 - CAUTION:

7-25 7.2.2 11 22 System Control Under System Control, you make settings that control specific functions of the complete system. NOTE: Under this menu

Pagina 21 - (Default)

7-26 System Control: Quick-Key Parameter Default Range 11 22 0606 Bell Squawk YES YES/NO YES: The following signals are emitted by the external s

Pagina 22

7-27 System Control: Quick-Key Parameter Default Range 11 22 1414 Audible Jamming NO YES/NO Refers to Jamming Time, which is described on page 7-

Pagina 23

7-28 System Control: Quick-Key Parameter Default Range 11 22 2121 Arm Pre-Warning NOYES/NO YES: For the system, or every area for which an autom

Pagina 24

7-29 System Control: Quick-Key Parameter Default Range 11 22 2626 IMQ Install NO YES/NO YES: If a zone is open when the system is activated, th

Pagina 25

Contents Contents ...

Pagina 26

7-30 System Control: Quick-Key Parameter Default Range 11 22 3131 External Bell NO YES/NO YES: Select this setting if an external sounder is co

Pagina 27

7-31 7.2.3 11 33 Receiver Under Receiver, you can make settings that control the radio receiver of your ABUS wireless alarm system. To access the Rec

Pagina 28

7-32 Receiver: Quick-Key Parameter Default Range 11 33 22 Jamming Time No Jamming detection None, 10, 20 or 30 seconds The jamming time specifies th

Pagina 29

7-33 7.2.5 11 55 Labels Under System Label, you name the system and areas 1, 2 and 3, and change default names. To enter a new name: Use the buttons

Pagina 30

7-34 To access the System Label menu: 1. Select the main menu System as described on page 7-23. 2. In the System menu, press 55 to get to the System

Pagina 31

7-35 7.2.6 11 66 Tamper Sound In the Tamper Sound menu, you can define the sounds generated by the ABUS wireless alarm system following a tamper in a

Pagina 32

7-36 7.2.7 11 77 System Default Jumper In the Default Jumper menu, you enable or disable a software factory reset via the J9 jumper. To access the Def

Pagina 33

7-37 7.3 22 Zones The Zones menu enables you to train wireless detectors for the system, program zone types, and define zone dependencies. This is an

Pagina 34 - for partition 1

7-38 22 11 ZZZZ 33 Delete Deletes detectors. Confirm deletion with [Y] YES or [N] NO. To change the display, press . 22 11 ZZZZ 44 Supervision Se

Pagina 35

7-39 Parameter Quick-Key Parameter Default Range IMPORTANT INFORMATION: • If you selected one by one to program the zones individually, you are gui

Pagina 36

7.5.1 44 11 Authority ...

Pagina 37

7-40 22 22 22 Zone Label Under Zone label, you can define or edit a name up to 15 characters long for each zone. Under Parameters, press 22 to acc

Pagina 38 - To change the display

7-41 22 22 44 Zone Type When a detector triggers, it always sends a signal to the alarm system. For example: A motion sensor reacts to movement,

Pagina 39

7-42 22 22 44 ZZZZ + 0303 Exit(OP)/Entry Default for zone 1 Armed/internal Zone type Exit(OP)/Entry behaves like zone type Exit/Entry 1 except

Pagina 40

7-43 22 22 44 ZZZZ + 0303 Exit(OP)/Entry Default for zone 1 Armed/internal Zone type Exit(OP)/Entry behaves like zone type Exit/Entry 1 excep

Pagina 41

7-44 22 22 44 ZZZZ + 1010 I+Instant (Interior+Instant) Armed The I+Instant zone type is similar to zone type Instant. However, this zone type is

Pagina 42

7-45 22 22 44 ZZZZ + 1818 Exit Termination A zone with the Exit Termination zone type behaves like a zone with the Exit(OP)/Entry zone type. Howe

Pagina 43

7-46 22 22 44 ZZZZ + 1818 Exit Termination A zone with the Exit Termination zone type behaves like a zone with the Exit(OP)/Entry zone type.

Pagina 44

7-47 22 22 55 Zone Sound Under Zone sound, you can, for each zone, define the alarm signal individually that is triggered when the alarm system is

Pagina 45

7-48 22 22 66 Force Arm The Force Arm setting for a zone enables the system to be activated even if one or more zones are open, provided these zones

Pagina 46

7-49 22 33 22 Soak Test Some wireless detectors tend to trigger alarms more than others. The Soak Test was developed to test these detectors

Pagina 47

Chapter 11 Example of an installation plan ...

Pagina 48

7-50 Editing Quick-Key Parameter 22 44 11 Copy to a zone Copies all settings programmed for a zone (except the zone name). 1. Press 11. You see the f

Pagina 49

7-51 7.3.5 22 55 Cross Zone Default: No cross-zone dependency Cross-zone dependency is an ideal function for making a system safer against false alarm

Pagina 50

7-52 7.4 33 Outputs Under Outputs, you program the relay and transistor outputs of the system. You link different system events to the activation of t

Pagina 51

7-53 33 11 UOUO11 0202 No Telephone Line The switch output is activated if a break in the telephone line is detected. It is deactivated after the tele

Pagina 52

7-54 33 11 UOUO22 0606 Panic Follow The switch output is activated if a panic alarm is triggered in the selected area(s) or if the (PANIC) alarm butt

Pagina 53

7-55 33 11 UOUO22 1818 Bell Stay Off The switch output is activated as follows: • If the system is activated externally (AWAY), the switch output

Pagina 54

7-56 Output mode An output mode has to be set for every output. This table gives an overview of the different output modes: Outputs Quick-Key Paramet

Pagina 55

7-57 Activation/Deactivation If the switch output follows more than one area or zone, you can use different patterns for activating and deactivating t

Pagina 56

7-58 7.5 44 Codes Under Codes, you can define user and installer Codes, define authorities, and assign areas. The ABUS wireless alarm system also has

Pagina 57

7-59 Authority Levels The Authority Levels menu option contains settings for the following authorities: Grand Master: There is only one Grand Master

Pagina 58

Chapter 1 Usage in accordance with regulations The ABUS wireless alarm system is used for protecting flats and homes and small to medium business obj

Pagina 59

7-60 7.5.2 44 22 Partition Default: Partition 1 Under Partition, you assign to user PINs partitions for which you have authority. The Grand Master is

Pagina 60

7-61 7.5.4 44 44 Installer Default: 0133 With the installer PIN, you have access to the installer menu and thus the authority to change all system par

Pagina 61

7-62 7.5.6 44 66 Code Length Default: four digits Under Code Length, you can change the number of digits used (4 or 6) for the Grand Master, the Manag

Pagina 62

7-63 7.6 55 Dialer The Dialer menu enables you to transmit alarms as voice text by telephone. In this menu, you also make the settings necessary for p

Pagina 63

7-64 Access Code and ID Quick-Key Parameter Default 55 55 11 Access code 5678 Defines an access code for remote programming. The four-digit access

Pagina 64

7-65 Controls Quick-Key Menu option Default 55 66 0202 FM Enable NO YES: Enables FM (= Follow Me) transmission. (See also Follow Me, page 7-68.) En

Pagina 65

7-66 Controls Quick-Key Menu option Default 55 66 1010 Answering Machine Override YES YES: Answering machine override is activated. • The upload/

Pagina 66 - • Press to exit the menu

7-67 Dialer: Parameter Quick-Key Parameter Default Range 55 77 44 11 Wait 6 seconds Press 11 followed by . 55 77 44 22 Wait 9 seconds Press 22 follo

Pagina 67

7-68 Dialer: Parameter Quick-Key Parameter Default Range 55 77 88 Swinger Limit 00 00 to 15 The Alarm Limit option is provided to prevent multiple

Pagina 68 - on BTO (bell time out)

7-69 7.6.5 55 99 Follow Me (FM) Under this menu option, you define the forwarding of an alarm as a voice text to a telephone or a security service. In

Pagina 69

3-7 Chapter 3 Introduction to the ABUS wireless alarm system Congratulations – you made the right choice! The ABUS wireless alarm system offers you pr

Pagina 70

7-70 Follow-Me Quick-Key Parameter Default 55 99 22 Events restore Defines whether a new call is made if the event (from section 5.9.1) is reset.

Pagina 71

7-71 7.7 77 Key-fobs Under key-fobs, you learn how to train up to eight 4-button key-fobs with rolling code to work with the ABUS wireless alarm syste

Pagina 72

7-72 7.7.2 77 22 Parameters Under Parameters, you program the function and the keys of the remote control. The four buttons of the remote control can

Pagina 73

7-73 8. You see the following on the display: 9. For button 3 (small button), you can choose between the following functions:  None: The butto

Pagina 74

7-74 7.8 88 Keypads Under Keypads, you can assign two operating panels to the ABUS wireless alarm system. The following is an overview of the menu op

Pagina 75

7-75 7.8.2 88 22 Communication Test Under Communication Test you test the radio communication between your wireless operating panel and the system. To

Pagina 76

7-76 7.9.1 99 11 Allocation Here you can allocate a new sounder to your system. To access the Allocation menu: 1. Select the Siren menu. 2. Under Si

Pagina 77

7-77 7.9.2 99 22 Parameter Under this menu option, you can change the sounder settings. You can change the following settings: • Volume • Flash frequ

Pagina 78

7-78 7.9.3 99 33 Communication test Under communication test you test the radio communication between your sounder and the system. To access the commu

Pagina 79

7-79 7.9.5 99 55 Tamper Mute Under Tamper Mute, you can deactivate the tamper function of the sounder for the current programming process. This enable

Pagina 80

3-8 3.2 What is the ABUS wireless alarm system? The ABUS wireless alarm system is an alarm system specially designed and developed for house owners an

Pagina 81

7-80 7.10 00 Exit Programming Under Exit Programming, all your settings in the installer menu are saved and you exit the installer menu. Important: T

Pagina 82

8-81 Chapter 8 Programming within the user programming menu This chapter explains an important menu option in the user menu. This menu option is for p

Pagina 83

8-82 8.1.1 77 11 Message structure Under Message structure, you define the sequence in which the voice messages are transmitted. To define a message

Pagina 84

8-83 8.1.2 77 22 Voice message labels Under voice message labels, you define names for zones, partitions, utility outputs and macro keys, and you find

Pagina 85

8-84 Voice message: message name Quick-Key Parameter Default Range 77 22 22 Zone message Press 22. You see the following on the display: Press

Pagina 86

8-85 Message Labels Quick-Key Parameter Default Range 77 22 33 Partition Message Press 33. You see the following on the display: Press or

Pagina 87

8-86 Message Labels Quick-Key Parameter Default Range 77 22 44 Utility output message NOTE: The switch output must be defined as an FM code

Pagina 88

8-87 8.1.3 77 33 Test Message Under Test Message, you can test recorded and assigned voice announcements. To conduct a Test message: 1. Select the

Pagina 89

8-88 8.1.4 77 44 Local Announcement Messages Under this menu option, you adapt local voice announcements to your requirements. To activate/deactivate

Pagina 90

8-89 8.2 Walk test Under the Walk test menu option, you can test your installation. When the system is in walk-test mode, you can trigger detectors wi

Pagina 91 - Chapter 10 Brief guide

3-9 The following graphic gives you an overview of further function properties of your ABUS wireless alarm system:

Pagina 92

9-90 Chapter 9 Accessories for your ABUS wireless alarm system The following is a list of accessories for your ABUS wireless alarm system. Wireless m

Pagina 93

10-91 Chapter 10 Brief guide This chapter explains the installation steps shown on the DVD for the ABUS wireless alarm package including a smoke detec

Pagina 94

10-92 10.2 Training the detectors for the ABUS wireless alarm system 10.2.1 Installer menu of the ABUS wireless alarm system • First press the star

Pagina 95

10-93 10.2.3 Programming zones You do not have to program the zones for the detectors in your package. They are already programmed for you as follows:

Pagina 96

10-94 10.4 Exiting the installer menu All wireless components in the package are now trained. Your ABUS wireless alarm system is almost ready for oper

Pagina 97

10-95 • Confirm the menu option phone number 1 with the Enter button. • On the system keypad, enter the number with local area code and if necess

Pagina 98

11-96 Chapter 11 Example of an installation plan The following table provides an overview of the information your installation plan should contain: P

Pagina 99

11-97 Partition Zone number Detector Zone type Name 1 2 3 4 5 6 7 8 9 10 11 12

Pagina 100 - EVENT MESSAGE DESCRIPTION

11-98 Appendix A: Event Log Messages This appendix provides descriptions of all the Event Log messages(ver 1.2xx) EVENT MESSAGE DESCRIPTION Activate

Pagina 101

11-99 EVENT MESSAGE DESCRIPTION Foil Z=XXX Trouble in foil (Day) zone No. XXX Forced P=X Partition X is force armed Found Z=XXX Wireless zone fou

Comentarios a estos manuales