Exit(OP)/Entry
Default for zone 1
A
rmed/internal
Zone type Exit(OP)/Entry behaves like zone type Exit/Entry 1 except that the zone does
not have to be closed at the moment of activation. However, the zone must be closed
before the exit delay time expires, or otherwise there is an alarm. This zone type is usually
assigned to opening contacts on front and side doors.
22
22
44
ZZZZ
+
0404
Entry follower
A
rmed/internal
Zone type Entry follower does not trigger an alarm if an entry delay time is started first. If
no entry delay is active, this zone triggers an alarm immediately if the area is activated. This
zone type is usually assigned to motion sensors that monitor the entrance area, in addition
to opening contacts on the entrance doors.
22
22
44
ZZZZ
+
0505
Instant
A
rmed/internal
If the area is active, the Instant zone type triggers an alarm immediately when the zone is
opened. This zone must not be opened during the entry and exit delay period. This is the
usual zone type for motion and opening sensors that are not in the entrance area.
22
22
44
ZZZZ
+
0606
I+Exit/Entry 1
(Interior + Exit/Entry 1)
Default for zone 2
A
rmed
The I+Exit/Entry 1 zone type is similar to zone type Exit/Entry 1. However, this zone type
is not monitored for an internally activated system.
IMPORTANT INFORMATION:
To shorten the exit delay time, press twice. This sets the entry delay time to 0. If
this zone is now opened, there is an immediate alarm.
22
22
44
ZZZZ
+
0707
I+Exit/Entry 2
Interior+Exit/Entry 2)
A
rmed
See above. However, for zones of this type, the times of Group 2 apply.
22
22
44
ZZZZ
+
0808
I+Exit(OP)/Entry
(Interior+Exit(OP)/Entry)
A
rmed
The I+Exit(OP)/Entry zone type is similar to zone type Exit(OP)/Entry. However, this zone
type is not monitored for an internally activated system.
22
22
44
ZZZZ
+
0909
I+Entry follow
(Interior+Entry Follower)
A
rmed
The I+Entry follow zone type is similar to zone type Entry Follower. However, this zone
type is not monitored for an internally activated system.