Deletes detectors. Confirm deletion with [Y] YES or [N] NO. To change the display,
press
.
22
11
ZZZZ
44
Supervision
Select whether a zone is to be monitored for regular reporting by the detectors to
the alarm system. Set the monitoring time in the System menu under Timers. If
surveillance is active for the detector and the detector does not report in the
defined time, an alarm is triggered. Select [Y] YES or [N] NO. To change the
display, press . To confirm, press .
7.3.2
22
22
Parameters
Under Parameters, you can make settings for programming properties of the zones. You can program all settings one by one for a
zone, or you define the respective parameters for all zones. If this is your first installation, you are recommended to select One by One.
If you make changes later, you can program the parameters directly in this menu.
You can first program the zones and then train the wireless detectors, or vice versa.
• One by one
• Zone Label
• Partitions
• Type
• Zone Sound
• Force Arming
Parameter
Quick-Key Parameter Default Range
22
22
11
One by one
The one by one option enables you to program the parameters individually for
each zone – i.e., one zone after the zone.
1. Enter a two-digit number to start programming (e.g. 01) and press
to
access the zone label menu option.
2. Enter a name for the zone and press
to go to the next menu option.
3. Press [1] to [3] to switch the state of the partition between [Y] YES and [N] NO. A
zone must be assigned to at least one area. Press to go to the next menu
option.
4. To program the zone type and make the other settings for the zone, select the
following menu options.
Type: Select a type and press
.
Zone sound: Select a signal type and press .
For further information about zone types and zone signals, see the next pages.
.