7-26
System Control:
Quick-Key Parameter Default Range
11
22
0101
Quick arm YES
YES/NO
YES: No user PIN is necessary for activating the system or an area.
NO: A user PIN is necessary for activating the system or an area. Choose this setting if
the alarm system or an operating panel is accessible to the public or to children.
11
22
0202
Quick UO YES
YES/NO
YES: A user can activate a switch output without a user PIN.
NO: A user PIN is necessary to activate a switch output.
11
22
0303
Allow Bypass YES
YES/NO
YES: A zone can be omitted (excluded from surveillance) by an authorised user.
NO: Omitting zones from surveillance is not possible.
11
22
0404
Quick Bypass
NO
YES/NO
YES: No user PIN is required for omitting a zone.
NO: A user PIN is required for omitting a zone.
11
22
0505
False Code Trouble YES YES/NO
YES: If an incorrect user PIN is entered three times, the operating panel is locked and, if
programmed, an alarm is sent by telephone. Bad PIN input is displayed as a fault on
the operating panel.
NO: If an incorrect user PIN is entered three times, the operating panel is locked and a
local alarm is sounded.
11
22
0606
Bell Squawk YES YES/NO
YES: The following signals are emitted by the external sounder to acknowledge
whether you have successfully activated/deactivated the system:
One tone means that the system is activated.
Two tones mean that the system is deactivated.
Four tones mean that the system is deactivated following an alarm.
NO: No confirmation is made by the sounder.
11
22
0707
Bell 30/10 NO
YES/NO
YES: The sounders interrupt the alarm tone for 10 seconds every 30 seconds.
NO: The sounders emit continuous alarm tones without interruption.
11
22
0808
Phone Cut Alarm NO YES/NO
YES: Monitors the telephone line and activates the sounder if the telephone line is
cut for the period defined under Phone Line Cut Delay Time. (See also
Phone Line Cut Delay time on page 7-25.)
NO: The telephone line is not monitored and there is no alarm.
11
22
0909
3 Minute Bypass NO
YES/NO
YES: After the system has been supplied with power, zones are automatically
omitted for 3 minutes to give detectors a chance to stabilise.
NO: The zones are monitored as soon as the system is activated.
11
22
1010
Audible Panic NO YES/NO
YES: In the event of a panic alarm, an audible alarm is issued.
NO: In the event of a panic alarm, it is transmitted by telephone. The system does not
trigger any audible alarms locally.