7-27
System Control:
Quick-Key Parameter Default Range
11
22
1111
Buzzer Bell NO YES/NO
YES: If the system is activated internally and an alarm is triggered, an alarm is
sounded for 15 seconds on the operating panels before the system activates
the external sounders and the alarm is transmitted by telephone.
NO: If the system is activated internally and an alarm is triggered, the external
sounders and the telephone line are activated immediately.
11
22
1212
Fire Temporal Pattern YES YES/NO
YES: The fire signals of the internal and external sounders are three increasing alarm
tones followed by a pause.
NO: The fire signals of the internal and external sounders are two seconds of continuous
tone followed by two seconds’ pause.
11
22
1313
Code Grand Master NO YES/NO
YES: Only a user with Grand Master authority can change user PINs and the time
and date.
NO: Users at the Master and Manager level can also change user PINs and the
time and date.
11
22
1414
Audible Jamming NO
YES/NO
Refers to Jamming Time, which is described on page 7-30.
YES: If the defined jamming time is reached, the ABUS wireless alarm system
activates the sounders. (See Jamming Trouble, page 7-32.)
NO: Jamming does not trigger an audible alarm.
11
22
1515
Technician Tamper NO
YES/NO
YES: The program PIN is required for resetting a tamper alarm. First, the OK
message must be received from the detector or the tamper zone must be
closed.
NO: A tamper alarm is reset with the OK message of the detector or when the
tamper zone is closed.
11
22
1616
Technician Reset NO
YES/NO
YES: Following an alarm, the program PIN must be entered to be able to reactivate the
system.
NOTE:
Before the Ready LED can light up, all zones in this area must be closed.
NO: The alarm system can be activated immediately following an alarm if all zones are
closed and the Ready LED is on.
11
22
1818
Summer/Winter Clock YES YES/NO
YES: The ABUS wireless alarm system automatically puts its clock forward
one hour forward in spring (last Sunday in March) and one hour back in
autumn (last Sunday in October).
NO: No automatic time adjustment
11
22
1919
Forced Keyswitch Arming YES
YES/NO
YES: If the system or an area is activated by a key-switch, all open zones are
automatically omitted from monitoring. The remaining zones are monitored. The
system/area is monitored in every case.
NO: The system/area can be activated only if all zones are closed and the system/area
is ready for activation.