System Control:
Quick-Key Parameter Default Range
11
22
2020
Pager NO
YES/NO
Enables alphanumeric output of system events on a pager. The number of the pager
must be programmed like a Follow-Me number.
YES: For the activated/deactivated event and the alarm event, the system sends
information to the pager.
NO: The system transmits no events to pagers.
11
22
2121
Arm Pre-Warning
NO
YES/NO
YES: For the system, or every area for which an automatic activation function was
programmed, a warning signal of 255 seconds is generated on the operating
panels and the alarm system prior to activation.
During this countdown, you can enter a valid user code to delay automatic
activation of the system/area by 45 minutes.
If activation of the system/area is delayed in this way, automatic activation of the
system is deactivated on the following days.
The 255-second warning does not apply to automatic internal activation.
NO: The system/area for which an automatic activation function is programmed is
activated automatically every day, regardless of whether automatic activation is
delayed or not.
11
22
2222
Low Battery Arm YES
YES/NO
YES: The system can be activated even if the standby batteries are not fully
charged or inserted.
NO: The system cannot be activated in the event of a battery fault.
11
22
2323
Eng. Tamper NO
YES/NO
YES: The system cannot be activated following a tamper alarm. The program
PIN first has to be entered.
NO: The system can be reactivated following a tamper alarm without the entry
of the program PIN.
11
22
2424
Blank Display NO YES/NO
YES: In operation mode, the LCD display is switched off for one minute after the
last input. To reactivate the display, a valid user PIN must be entered.
NO: The LCD display is always on.
11
22
2525
24 Hour Bypass YES
YES/NO
YES: A user can omit a 24-hour zone.
NO: A user cannot omit a 24-hour zone.
11
22
2626
IMQ Install NO YES/NO
YES: If a zone is open when the system is activated, the system is activated but an alarm
is generated when the exit delay time expires.
NO: Open zones are automatically omitted following expiry of the exit delay time.
11
22
2727
Grand Master
Authority/Partition
YES
YES/NO
YES: Areas and authority levels can be changed by the installer in the installer menu and
in the user menu using a Grand Master pin.
NO: Areas and authority levels can only be changed by the installer in the installer menu.
11
22
2828
Disarm Stop FM YES YES/NO
YES: Forwarding of calls is stopped when the system is deactivated.
NO: Forwarding of calls is continued even if the system is deactivated.
NOTES:
If a block lock is used, you can deactivate the system only if the block lock is opened.
However, if the system is deactivated by telephone, the calls are continued.